ABOUT SWR PIPES & FITTINGS

SUPREME GOLD is pioneer in introducing most cost effective & efficient drainage system (S.W.R.) which is fast replacing most of the conventional systems used in building industry. SUPREME GOLD SWR pipes & fittings are manufactured in both ringfit & selfit with two different class named as

Type A – Pipes are recommended for use in ventilation pipe work & rain water application &

Type B – Pipes are recommended for use in soil & waste discharge systems.

ADVANTAGES

The PVC Protector Casing have several advatages over conventional steel well casings.

  • Non toxic
  • Corrosion resistant
  • Light weight
  • Long Lasting
  • Easy installation
  • Higher well yields

PRECAUTIONS

  • Use non return valves for water raising system
  • Use couplers if the length is too long. It also assists for maintenance.
  • Use proper adapter while fixing with the existing GI / CI or AC pipe system.
  • Provide support at joints & at regular distance. Avoid inclined bends.
  • Prefer underground or ducted system to increase life.

STANDARD SPECIFICATIONS

Standards & Specifications:

  • IS 14735 – Specification for SWR Fittings.
  • IS 13592 – Specification for SWR Pipes

Material:

  • PVC Compound Grade Equivalent to PVC 1120 / 2120

Sizes:

  • Pipes : 50mm, 75mm, 90mm, 110mm & 160mm
  • Fittings : 50mm, 75mm, 90mm, 110mm & 160mm

Colour:

  • Dark Gray
  • Light Gray

Features and Properties

  • UV Stabilized
  • High Chemical & Corrosion Resistance
  • Stronger, Resilient and Long Lasting
  • Environment Friendly

Areas of Applications:

  • Drain & Sewer systems in Residences, Commercial Complexes.
  • Resorts, Hospitals, Academic Institutes and Industries etc.

INSTALLATION GUIDE

Make sure that spigot end and inside of socket is clean and the sealing ring is placed evenly in the socket.
When cutting pipes make sure they are cut square. Chamfer the end cut to an angle of 150 with a medium file.
A correct depth of entry of the spigot into the socket is required to allow thermal movement. To achieve this, push spigot fully into the socket (remove sealing ring at this time) and make a mark on the spigot. Withdraw the spigot by 10mm & mark the spigot with a bold line. This bold mark indicates the correct depth of entry to allow the necessary expansion gap.
Smear SUPREME GOLD rubber lubricant evenly on the chamfered spigot and the sealing ring. Then insert the spigot into socket with light twisting motion. Pull out the pipe to allow 10mm expansion gap.
The joint is now complete and requires no additional mastics, tape or cement or any other joining sealants.

APPROX CONSUMPTION OF RUBBER LUBRICANT

Size in mm No. of joints / kg
50
75
90
110
160
900
500
350
300
200

MAXIMUM SUPPORT DISTANCE IN METERS

Size in mm Horizontal Vertical
40
50
75
90
110
160
0.4
0.5
0.75
0.9
1.1
1.6
1.20
1.5
2.00
2.00
2.00
2.00

ADVANTAGES

  • High standards & wide range
  • Mirror smooth bore-no chocking
  • Excellent chemical & corrosion resistance
  • Light weight – easy handling
  • High impact strength
  • UV – stabilized (all weather resistence)
  • 100% leak proof joints
  • Longer life
  • Easy cleaning
  • Quick convenient installation
  • Quick testing
  • No filling material required for jointing
  • Least maintenance
  • Can be coloured as per choice to match building aesthetics
  • Economical

PRECAUTIONS

  • Only UV stabilized UPVC SWR pipes with rubber ring should be used. The regular UPVC Pipes with solvent cement joining when exposed to sun-rays/weather get brittle and brownish.
  • Use only rubber lubricant for joining SWR Pipes & Fittings, where rubber ring is used.
  • Avoid over tightening of door caps. Proper placement of rubber ring should be confirmed before tightening.
  • Avoid misalignment of vertical SWR Pipe stacks and incorrect spacing of Pipe clips.
  • Cutting of UV stabilized SWR Pipe should be straight as diagonal cutting may lead to leakage.
  • All entry to main stacks should be protected with water seal trap, wherever there is mixing of Soil & Waste lines.
  • Keep a gap of 10mm between all UV stabilized SWR Pipes and Fittings to accommodate thermal expansion and contraction of pipes for longer life of the system.
  • Smoke Test should be avoided and test plug / socket plug should be used for testing the lines.
  • Horizontal lines within bathrooms should be cement encased and tested before compacting of sunken floor to avoid any accidental damages.
  • For further technical information / assistance, the manufacturer to be contacted for required clarification.

SWR FITTING

SIZE (Inch) SIZE (MM) Packing                     MRP
Regular “O” Ring Fit Self Fit (Pesting) Special “O” Ring Fit
2½” 75 80 /50 36.43 32.34 76.43
4″ 110 60 /25 65.02 61.28 105.02
SIZE (Inch) SIZE (MM) Packing                    MRP
Regular “O” Ring Fit Self Fit (Pesting) Special “O” Ring Fit
4 x 2½” 110 X 75 75 62.98 58.30 82.98
SIZE (Inch) SIZE (MM) Packing                    MRP
Regular “O” Ring Fit Self Fit (Pesting ) Special “O” Ring Fit
4 x 2½” 110 X 75 24 134.81 126.30 174.81
SIZE (Inch) SIZE (MM) Packing                    MRP
Regular “O” Ring Fit Self Fit (Pesting ) Special “O” Ring Fit
4 x 2½” 110 X 75 20 155.57 147.06 195.27
SIZE (Inch) SIZE (MM) Packing                  MRP
Regular “O” Ring Fit Self Fit (Pesting ) Special “O” Ring Fit
2½” 75 32 44.10 40.27 64.10
4″ 110 55 85.79 81.11 105.79
SIZE (Inch) SIZE (MM) Packing                     MRP
Regular “O” Ring Fit Self Fit (Pesting) Special “O” Ring Fit
2½” 75 65 54.13 50.30 74.13
4″ 110 36 112.34 107.66 132.34
SIZE (Inch) SIZE (MM) Packing                    MRP
Regular “O” Ring Fit Self Fit (Pesting ) Special “O” Ring Fit
2½” 75 60 70.47 66.64 90.47
4″ 110 30 146.38 141.70 166.38
SIZE (Inch) SIZE (MM) Packing                      MRP
Regular “O” Ring Fit Self Fit (Pesting ) Special “O” Ring Fit
2½” 75 48 69.45 61.79 109.45
4″ 110 24 147.74 138.38 187.74
SIZE (Inch) SIZE (MM) Packing                    MRP
Regular “O” Ring Fit Self Fit (Pesting ) Special “O” Ring Fit
2½” 75 40 88.18 80.51 128.14
4″ 110 20 189.62 180.26 229.62
SIZE (Inch) SIZE (MM) Packing                     MRP
Regular “O” Ring Fit Self Fit (Pesting) Special “O” Ring Fit
2½” 75 36 91.91 84.25 131.91
4″ 110 20 183.15 173.79 223.15
SIZE (Inch) SIZE (MM) Packing                     MRP
Regular “O” Ring Fit Self Fit (Pesting) Special “O” Ring Fit
2½” 75 24 114.38 102.89 174.38
4″ 110 16 226.04 212.00 286.04
SIZE (Inch) SIZE (MM) Packing                      MRP
Regular “O” Ring Fit Self Fit (Pesting ) Special “O” Ring Fit
2½” 75 18 142.98 131.49 202.98
4″ 110 12 276.77 262.73 336.77
SWR PIPES – TYPE  “A” (Length – 10 Ft.)
SIZE IN MM 75MM 110MM 160MM
SIZE IN INCH 2½” 4″ 6″
MRP 177.00 356.00 680.00
SIZE (Inch) SIZE (MM) Packing                    MRP
Regular “O” Ring Fit Self Fit (Pesting) Special “O” Ring Fit
2½” 75 32 86.13 74.64 146.13
4″ 110 16 174.30 160.26 234.30
SIZE (Inch) SIZE (MM) Packing                     MRP
Regular “O” Ring Fit Self Fit (Pesting ) Special “O” Ring Fit
2½” 75 26 107.91 96.42 167.91
4″ 110 16 219.57 205.53 279.57
SIZE (Inch) SIZE (MM) Packing                    MRP
Regular “O” Ring Fit Self Fit (Pesting ) Special “O” Ring Fit
2½” 75 60 73.53 69.70 93.53
4″ 110 40 138.90 134.22
SIZE (Inch) SIZE (MM) Packing  MRP
2½” 75 120 13.62
4″ 110 56 30.98
SIZE (Inch) SIZE (MM) Packing   MRP
2½” 75 60 17.02
4″ 110 70 22.13
SIZE (Inch) SIZE (MM) Packing  MRP
2½” 75 300 15.32
4″ 110 150 30.64
SIZE (Inch) SIZE (MM) Packing  MRP
4 x 2½” 110 X 75 40 118.13
4 X 3″ 110 X 90 32 131.40
4 X 4″ 110 X 110 24 142.98
SIZE (Inch) SIZE (MM) Packing  MRP
4 x 2½” 110 X 75 40 103.49
4 X 3″ 110 X 90 32 116.40
4 X 4″ 110 X 110 24 127.98
SIZE (Inch) SIZE (MM) Packing  MRP
4 x 2½” 110 X 75 26 149.79
SIZE (Inch) SIZE (MM) Packing  MRP
4 x 2½” 110 X 75 26 112.34
SIZE (Inch) SIZE (MM) Packing  MRP
4 X 4″ 110 X 110 24 226.38
4 X 4¾” 110 X 125 24 236.60
SIZE (Inch) SIZE (MM) Packing  MRP
4 X 4″ 110 X 110 24 281.19
4 X 4¾” 110 X 125 24 411.60
SIZE (Inch) SIZE (MM) Packing  MRP
4 X 4″ 110 X 110 24 251.91
4 X 4¾” 110 X 125 24 263.15
SIZE (Inch) SIZE (MM) Packing  MRP
4 X 4″ 110 X 110 100 39.70
4 X 4¾” 110 X 125 100 32.70